The water surge volume in the drawoff leg is found from criteria in Section 333. This is the volume between maximum and minimum levels shown in Figure 300-6. The rate at which 100-micron oil droplets will move upward is found from Equation 300-8 (or 300-7). Size the diameter of the drawoff leg so that the water velocity downward is less than the oil droplet velocity upward.